SP1200 MUSIC CONTROLLER
INPUTS
OFF
3
0
3
6
9
15
30
55
1234
ON
OL
STATUS
POWER
COMM PORT
ZONE A
MASTER
VOLUME
PHANTOM
PAGING
GAIN +40dB
MIC /LINE INPUT A
CAUTION: TO REDUCE THE
RISK OF FIRE REPLACE WITH SAME
TYPE FUSE AND RATING
115 V 60Hz FUSE 115/ T4A 120 WATTS
230 V 50Hz FUSE 230/ T2A 120 WAT TS
1234
12345678
0
I
PROGRAM EQ
1234
ZONE
A
GAIN +40dBPHANTOM
ON
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC
"MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA
PARALLEL
INPUTS
G
+
CONTROL
GROUND
ALL CALL
DIRECT
R
OUTPUT
PROGRAM INPUTS
1234
PRIORITY
L
HIGH
U
+12–12
U
+12–12
LOWGAIN
+
-
HIGH 12kFREQMIDLOW 80Hz
U
+15–15
U
+15–15
U
+15–15
1K
3K400
8k
250
HIGH
U
+12–12
U
+12–12
LOWGAIN
+
-
+
-
AMP IN
PRE OUT
PAGING MIC
EXPANSION IN EXPANSION OUT
AMP ADDRESS RS485 REMOTE
AMBIENT
MIC
MIC
VOX
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
CAUTION
AVI S:
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
SERIAL NUMBER
MANUFACTURING DATE
ZONE A
OUTPUT SUITABLE
FOR CLASS 2 WIRING
100/ 70V/8
+
1
2
3
G
+
A
G
B
12345678
LOCAL
1234
REMOTE
1234
SP1200
MUSIC CONTROLLER
SP1200 Single-Channel
Program Controller/Amplifier
Instruction Manual
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Program Controller/Amplifier

SP1200 MUSIC CONTROLLERINPUTSOFF303691530551234ONOLSTATUSPOWERCOMM PORTZONE AMASTERVOLUMEPHANTOMPAGINGGAIN +40dBMIC /LINE INPUT ACAUTION: TO REDUCE TH

Seite 2 - Table of Contents

SP1200 – 10ApplicationsA: Typical Mono ApplicationThis diagram depicts a typical setup, using theSP1200 in a mono application. A Digital SatelliteServ

Seite 3 - 2. Introduction

SP1200 – 11CAUTION: When using multiple SP1200sthat use the expansion bus, these switchsettings must be unique to each unit oryou can damage your SP12

Seite 4 - Rear Panel Features

SP1200 – 12Signal Pin No.Input 1 Left (+) Pin 1Input 1 Left (–) Pin 14Input 1 Right (+) Pin 2Input 1 Right (–) Pin 15Ground Pin 3Input 2 Left (+) Pin

Seite 5 - SP1200 – 5

SP1200 – 13Connecting the RS485 Serial PortThis is a 3-pin Phoenix-type connector thatfollows standard RS485 protocol. Select either adata-grade shiel

Seite 6 - 3. Installation

SP1200 – 14EQ BypassJumper J6, located on each Filter Board, allowsyou to bypass the 3-band EQ for the four ProgramInputs.Jumper pins 1 and 2 to bypas

Seite 7 - SP1200 – 7

SP1200 – 15AC Power ConsiderationsEach SP1200 draws an average of 3 amps of ACline current (@ 120VAC) when fully loaded andplaying music with a relati

Seite 8 - C: Expansion with Local Mic

SP1200 – 164. Operation• Bus Assign switches are used to assign aprogram input source to the balanced expansionbus. There are four switches for each p

Seite 9 - D: Room Combining—Zones

SP1200 – 17PAGING MIC CONTROLThe PAGING MIC CONTROL connector isprovided to connect a manual paging switch.Connect a normally-open switch between GND

Seite 10 - SP1200—Plan Ahead!

SP1200 – 18Using Inputs 1-4Connect the program sources to Inputs 1-4.These could include a CD player, tape deck, tuner,satellite feed, TV audio, jukeb

Seite 11 - Connections

SP1200 – 19Using the Paging MicThe paging mic is used to make announcementsover the system. If the paging mic is a condensermic or other type of mic t

Seite 12 - Connecting the Expansion Bus

SP1200 – 2CAUTION AVISRISK OF ELECTRIC SHOCK DO NOT OPENRISQUE DE CHOC ELECTRIQUENE PAS OUVRIRCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCKDO NOT R

Seite 13 - Internal Settings

SP1200 – 20Ambient Mic Calibration and Placement1. Connect the MT-3100 (or other microphone) to theAMBIENT MIC connector on the rear panel. Make suret

Seite 14 - EQ Bypass

SP1200 – 21Using the EQEach local MIC/LINE INPUT has a 2-bandequalizer for adjusting the lows or highs on themicrophone signal. When the controls are

Seite 15 - Thermal Considerations

SP1200 – 22ADDRESS switch #6 in the Master position (up),and the other unit in the Slave position (down).In this way, you can have one Remote controlo

Seite 16 - 4. Operation

SP1200 – 2330369153055DIRECTOUTPUTLRINPUT 1DIGITALLYCONTROLLEDATTENUATORSDIGITALLYCONTROLLEDATTENUATORL+—RMACKIE INDUSTRIALSP1200BLOCK DIAGRAM(#01.02.

Seite 17 - SP1200 – 17

SP1200 – 24SP1200 MUSIC CONTROLLERSP1200 SpecificationsPower Amplifier SectionContinuous Sine Wave Average Output Power, single channeldriven:200 watt

Seite 18 - Using the 3-Band EQ

SP1200 – 25DisclaimerMackie Industrial continually engages in researchrelated to product improvement, new materials, andproduction methods. Design ref

Seite 19 - Using the Ambient Mic

SP1200 – 26Appendix B: Button ModesPress 1 on Power Up: AGC Reset• Press and hold the Input 1 button while powering up the SP1200.• Release the Input

Seite 20 - Setting the GAIN

SP1200 – 27MACKIE DESIGNS. ™RISK OF FIRE! REPLACE WITH FUSE AS MARKED© 2000®055-286-00 REV:__SP2400:SOFT STARTR1C1C3R4R3R6D1F1J3J1J4J2J8J5J11J14J9J6J1

Seite 21 - Using the RS485 Connection

SP1200 Music ControllerMackie Industrial16220 Wood-Red Rd. NE • Woodinville, WA 98072 • USA888/337-7404 • Outside the U.S.: 425/487-4333Fax: 425/487-

Seite 22 - Upgrading the Software

SP1200 – 3Audio expansion connectors are provided on therear panel for connecting multiple SP1200s, withshared audio via balanced busing. Each of the

Seite 23 - 5. Specifications

SP1200 – 4Front Panel FeaturesINPUTS select buttons are used to choose theprogram source for the zone. Only one source maybe selected at a time. These

Seite 24 - SP1200 Specifications

SP1200 – 5The PAGING MIC VOX variable control adjuststhe ducking threshold for the paging mic. Rotate thecontrol clockwise to reduce the threshold. Ro

Seite 25 - Appendix A: Default Settings

SP1200 – 63. InstallationApplication DiagramsPHANTOMPAGINGGAIN +40dBMIC /LINE INPUT ACAUTION: TO REDUCE THERISK OF FIRE REPLACE WITH SAMETYPE FUSE AN

Seite 26 - Appendix B: Button Modes

SP1200 – 7PHANTOMPAGINGGAIN +40dBMIC /LINE INPU T ACAUTION: TO REDUCE THERISK OF FIRE REPLACE WITH SAMETYPE FUSE AND RATING 115V 60Hz FUS E 115/ T4

Seite 27 - Make sure

SP1200 – 8INTERNAL BUS ASSIGN SWITCHESS1S512345678ON12345678ONINTERNAL BUS ASSIGN SWITCHESSP1200 SWITCH SETTINGS123456780IZONE AAMBIENT MIC OFF/ONOFF

Seite 28 - SP1200 Music Controller

SP1200 – 9D: Room Combining—ZonesNote: This application provides independent source selection for each zone, or common inputsource selection for both

Kommentare zu diesen Handbüchern

Keine Kommentare